Comparison of Fibrinogen Concentrates2021-11-14T22:41:24+00:00

Comparison of Activity in Other Available FC Products

Differences in the biochemical composition of plasma derived human fibrinogen concentrates1

Fibryga® 4g Other Available FC
Fibrinogen Antigen (g) 3.0 3.3
Fibronectin (mg) 2.1 140
VWF Antigen (U) 30 570
FXIII Activity (U) 585 165

Note: based on in vitro studies

Lower fibronectin and VWF antigen may contribute to increased safety, and higher FXIII levels may contribute to increased efficacy

1. Neisser-Svae et al. Differences in the biochemical composition of three plasma derived human fibrinogen concentrates. Thrombosis Research. 2021;205;44-46